Fronius Primo GEN24 10.0 (208–240V) Hybrid Inverter | PV Point Backup | Dual MPPT
The Fronius Primo GEN24 10.0 (208–240V) is a hybrid PV inverter with dual MPPT inputs and integrated PV Point backup output, designed for 1~NPE 208/220/240V applications. Specs below are pulled directly from the provided “Primo GEN24 208–240” datasheet table.
Key Specifications
• Model – Fronius Primo GEN24 10.0 (Primo GEN24 208–240)
• Number of MPP trackers – 2
• DC input voltage range (Umin–Umax) – 65–600 V
• Nominal input voltage (Udc,r) – 365 V (208/220) / 385 V (240)
• Feed-in start voltage (Ustart) – 80 V
• Usable MPP voltage range – 65–480 V
• MPP voltage range (at rated power) – 260–480 V
• Max. usable input current (Imax) – 22 A (MPPT1) / 22 A (MPPT2)
• Max. short circuit current per MPPT (Isc) – 41.25 A (MPPT1) / 38 A (MPPT2)
• Number of DC connections – 2 (MPPT1) / 2 (MPPT2)
• Max usable DC power – 10,250 W (MPPT1) / 10,250 W (MPPT2) / 10,250 W (Total)
• Max PV generator output (Ppeak) – 13,500 Wpeak (208) / 13,000 Wpeak (220) / 15,000 Wpeak (240)
• AC rated power (Pac,r) – 9,450 W (208) / 10,000 W (220) / 10,000 W (240)
• Apparent power – 9,450 VA (208) / 10,000 VA (220) / 10,000 VA (240)
• Max output power – 9,450 W (208) / 10,000 W (220) / 10,000 W (240)
• Nom. AC output current – 45.45 A (208) / 45.45 A (220) / 41.7 A (240)
• Mains connection – 1~NPE 208 V / 220 V / 240 V (+10% / −12%)
• Frequency range (fmin–fmax) – 50 Hz / 60 Hz (45 Hz–66 Hz)
• Distortion factor – < 3.5 %
• Power factor (cos φ) – 0.8–1 ind./cap.
• PV Point nominal output power – 1,560 VA (120 V) / 2,860 VA (220 V) / 3,120 VA (240 V)
• PV Point nominal AC voltage – 1~NPE 120 V / 220 V / 240 V
• Switching time – < 35 sec
• Dimensions (height × width × depth) – 23.0 × 20.8 × 7.1 in (583 × 529 × 180 mm)
• Weight – 45.97 lb (20.85 kg)
• Protection class – Type 4X
• Protection class – 1
• Night consumption – < 10 W
• Overvoltage category (DC/AC) – 2/4
• Cooling – Active Cooling Technology
• Installation – Indoor and outdoor installation
• Ambient temperature range – −40 to +140 °F / −40 to +60 °C
• Permissible humidity – 0–100 %
• Noise emissions – < 52 dB(A)
• Max. altitude – 13,123 ft / 4,000 m
• DC insulation measurement – Integrated
• DC disconnector – Integrated
• Reverse polarity protection – Integrated
• Arc Fault Circuit Interruption (Arc Guard) – Integrated
• WLAN / 2 + Ethernet LAN – Fronius Solar.web, Modbus TCP, Fronius Solar API (JSON)
• 6 digital inputs – Connection to ripple control receiver, energy management
• 6 digital inputs/outputs – Integrated
• Emergency shutdown (WSD) – Integrated
• Data logger and web server – Modbus RTU (third-party) / Fronius Smart Meter
• Max. efficiency – 97.2 % (208) / 97.2 % (220) / 97.5 % (240)
• CEC (ηCEC) – 96.5 % (208) / 96.5 % (220) / 97 % (240)
• MPP adjustment efficiency – > 99.9 %
• Certificates and standard compliance – UL 1741 Third Edition (incl. UL1741 Supplement SA and SB), UL CRD – Non-Isolated EPS Interactive PV Inverters Rated Less Than 30kVA, UL1998 (for functions: AFCI, RCMU, PV Rapid shutdown monitoring), IEEE 1547-2018 incl. IEEE 1547a:2020, IEEE 1547.1-2020, IEEE 1547:2003 incl. IEEE 1547.1:2005, ANSI/IEEE C62.41, FCC Part 15 A & B, CSA C22.2 No. 107.1-16 (reaffirmed 2021), CSA C22.2 No. 200-19, CSA C22.2 No.330-23, CSA C22.3 No.9-20, UL1699B:2021
• Country of manufacture – Austria