Victron Energy Cyrix-i 12/24V-400A Intelligent Battery Combiner

Victron Energy
$352.17
(No reviews yet)
Current Stock:
Adding to cart… The item has been added

Victron Energy Cyrix-i 12/24V-400A Intelligent Battery Combiner

The Victron Cyrix-i 12/24V-400A is an advanced battery combiner designed for high-current DC systems. With automatic voltage-based switching and intelligent software logic, it safely connects and disconnects batteries without manual input—making it perfect for automotive, RV, marine, and off-grid energy systems operating at 12V or 24V.

This smart relay offers bidirectional sensing, starter battery prioritization, and zero voltage loss, making it a superior alternative to traditional diode isolators. Its rugged 400A continuous current rating and peak surge capacity of 2000A ensure reliable performance under heavy load conditions.

Key Specifications

  • Model – Cyrix-i 12/24V-400A

  • Type – Intelligent battery combiner / Voltage-sensitive relay

  • System Voltage – 12V or 24V DC (auto-sensing)

  • Continuous Current Rating – 400A

  • Peak Current Rating – 2000A (1 second)

  • Input Voltage Range (12/24V model) – 8–36 VDC

  • Connect/Disconnect Profiles – 4 programmable profiles based on voltage/time thresholds

  • Over-voltage Disconnect – 16V / 32V (depending on system)

  • Standby Current Consumption – <4 mA

  • Emergency Start Function – Yes (30 s manual push-button assist)

  • Remote Monitoring Support – Micro switch included

  • Status Indicator – Bi-color LED

  • Dimensions (H x W x D) – 78 x 102 x 110 mm (3.1 x 4.0 x 4.4 in)

  • Weight – 0.9 kg (2.0 lbs)

  • Connect Terminals – M8

  • Mounting – Surface-mountable design

Features & Benefits

  • Smart Voltage Monitoring – Monitors voltage trends, not just fixed thresholds, to prevent premature or false switching.

  • Auto Voltage Detection – Instantly adapts to 12V or 24V battery banks with no manual configuration.

  • Lossless Power Transfer – Avoids voltage drops commonly seen with diode isolators.

  • Bidirectional Operation – Will close the relay even if the auxiliary battery is charging from a source.

  • Starter Battery Protection – Always ensures the starter battery is charged before engaging auxiliary loads.

  • Emergency Parallel Mode – Manual override switch allows batteries to be joined in emergencies.

  • Selectable Profiles – Four connect/disconnect behavior modes are available for different system needs.

  • Failsafe Logic – Will not connect at low voltage (<2V) or disconnect prematurely due to dips.