Victron Energy MultiPlus Compact 24/2000/50-50 | 120V Inverter/Charger
The Victron MultiPlus Compact 24/2000/50-50 combines a pure sine wave inverter, adaptive battery charger, and fast AC transfer switch in one enclosure. Built for off-grid, mobile, and backup systems, it supports PowerAssist, PowerControl, and full system integration through VE.Bus.
Key Specifications
• Model – MultiPlus Compact 24/2000/50 (120V/60Hz)
• DC Input Voltage Range – 19–33 VDC
• Output Voltage – 120 VAC ±2%
• Output Frequency – 60 Hz ±0.1%
• Continuous Output Power @ 25°C / 77°F – 2000 VA / 1600 W
• Continuous Output Power @ 40°C / 104°F – 1450 W
• Continuous Output Power @ 65°C / 150°F – 1100 W
• Peak Power – 4000 W
• Maximum Efficiency – 94%
• Zero-Load Power – 11 W
• Zero-Load Power in AES mode – 8 W
• Zero-Load Power in Search mode – 4 W
• Charger Input Voltage Range – 95–140 VAC
• Charger Input Frequency – 45–65 Hz
• Charger Power Factor – 1
• Charge Voltage “absorption” – 28.8 VDC
• Charge Voltage “float” – 27.6 VDC
• Storage mode – 26.4 VDC
• Charge current house battery – 50 A
• Charge current starter battery – 4 A
• Battery temperature sensor – Yes
• Transfer switch – 50 A
• PowerControl – Yes
• PowerAssist – Yes
• Parallel and 3-phase operation – Yes
• VE.Bus communication port – For parallel and three phase operation, remote monitoring and system integration
• Remote on-off – Yes
• Operating temp. range – -40 to +65°C / -40 to 150°F (fan assisted cooling)
• Humidity (non-condensing) – max 95%
• Protection category – IP 21
• Material & Colour – aluminium (blue RAL 5012)
• Battery connection – M8 bolts
• 120V AC-connection – Screw-terminal 6 AWG (13 mm²)
• Dimensions (h × w × d) – 520 × 255 × 125 mm (20.5 × 10.0 × 5.0 in)
• Weight – 13 kg (25 lbs)
• Safety – UL 458, EN-IEC 60335-1, EN-IEC 62109-1
• Emission and immunity – EN-IEC 61000-3-2/-3-3, EN-IEC 61000-6-1/-6-2/-6-3
• Protection (a–g) – output short circuit; overload; battery voltage too high; battery voltage too low; temperature too high; 120 VAC on inverter output; input voltage ripple too high